BibTex RIS Cite

-

Year 2015, Volume: 18 Issue: 4, 351 - 358, 20.06.2015

Abstract

Objectives: The aim of this study was to evaluate the one-year clinical follow-up the two implant retained mandibular overdentures with locator attachments and conventional maxillary complete dentures.Materials and Methods: A total of 18 implants were placed in mandibular anterior region. 9 implant retained mandibular overdentures with locator attachment and conventional maxillary complete denture were fabricated after healing period. Follow up visits were performed every in 3 months during one-year follow-up. Implant survival rate, mechanic complications, periimplant tissue (marginal bone loss, presence of calculus) and patient satisfaction were evaluated.Results: Patient satisfaction was significantly higher in two implant retained overdenture with locator attachment in comparison with their earlier conventional complete denture. Implant survival rate was 100%. However no technical complication was detached in seven patients, patrix deformation was observed as a technical complication in two patients in the first six months. Patrixes were replaced with different colored plastic parts with less retention.Conclusions: Locator attachments in two implant retained mandibular verdenture is a successful treatment option in edentulous patients.Sorumlu yazar: Güliz Aktaş, Hacettepe Üniversitesi Diş Hekimliği Fakültesi, Protetik Diş Tedavisi A.D., 06100 Sıhhiye/Ankara, Türkiye, Tel: +90 312 305 2240, Fax: +90 312 311 3741 E-posta: dtgulizaktas@gmail.com

References

  • MacEntee MI, Walton JN, Glick N. A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: Three-year results. J Prosthet Dent 2005;93:28-37.
  • Boven GC, Raghoebar GM, Vissink A, Meijer HJA. Improving masticatory performance, bite force, nutritional state and patient's satisfaction with implant overdentures: a systematic review of the literature. J Oral Rehabil 2015;42:220-33.
  • Kimoto K, Garrett NR. Effect of mandibular ridge height on masticatory performance with mandibular conventional and implant-assisted overdentures. Int J Oral Maxillofac Implants 2003;18:523-30.
  • Thomason JM, Kelly SAM, Bendkowski A, Ellis JS. Two implant retained overdentures-A review of the literature supporting the McGill and York consensus statements. J Dent 2012;40:22-34.
  • Trakas T, Michalakis K, Kang K, Hirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent 2006;15:24-34.
  • Alsabeeha NHM, Payne AGT, Swain MV. Attachment Systems for Mandibular Two-Implant Overdentures: A Review of In Vitro Investigations on Retention and Wear Features. Int J Prosthodont 2009;22:429-40.
  • Cune M, Burgers M, van Kampen F, de Putter C, van der Bilt A. Mandibular Overdentures Retained by Two Implants: 10-Year Results from a Crossover Clinical Trial Comparing Ball-Socket and Bar-Clip Attachments. Int J Prosthodont 2010;23:310-17.
  • Krennmair G, Seemann R, Weinlander M, Piehslinger E. Comparison of Ball and Telescopic Crown Attachments in Implant-Retained Mandibular Overdentures: A 5-year Prospective Study. Int J Oral Maxillofac Implants 2011;26:598-606.
  • Elsyad MA, Al-Mahdy YF, Fouad MM. Marginal bone loss adjacent to conventional and immediate loaded two implants supporting a ball-retained mandibular overdenture: a 3-year randomized clinical trial. Clin Oral Implants Res 2012;23:496-503.
  • Cehreli MC, Karasoy D, Kokat AM, Akca K, Eckert S. A Systematic Review of Marginal Bone Loss Around Implants Retaining or Supporting Overdentures. Int J Oral Maxillofac Implants 2010;25:266-77.
  • Bilhan H, Mumcu E, Arat S. The comparison of marginal bone loss around mandibular overdenture-supporting implants with two different attachment types in a loading period of 36 months. Gerodontology 2011;28:49-57.
  • Cehreli MC, Uysal S, Akca K. Marginal Bone Level Changes and Prosthetic Maintenance of Mandibular Overdentures Supported by 2 Implants: A 5-Year Randomized Clinical Trial. Clin Implant Dent Relat Res 2010;12:114-21.
  • Ellis JS, Burawi G, Walls A, Thomason JM. Patient satisfaction with two designs of implant supported removable overdentures; ball attachment and magnets. Clin Oral Implants Res 2009;20:1293-98.
  • Geckili O, Bilhan H, Bilgin T. Impact of mandibular two-implant retained overdentures on life quality in a group of elderly Turkish edentulous patients. Arch Gerontol Geriatr 2011;53:233-36.
  • Balaguer J, Garcia B, Penarrocha M, Penarrocha M. Satisfaction of patients fitted with implant-retained overdentures. Med Oral Patol Oral Cir Bucal 2011;16:E204-E09.
  • Assuncao WG, Barao VAR, Delben JA, Gomes EA, Tabata LF. A comparison of patient satisfaction between treatment with conventional complete dentures and overdentures in the elderly: a literature review. Gerodontology 2010;27:154-62.
  • Troeltzsch M, Troeltzsch V, Brodine AH, et al. Clinical Performance and Peri-implant Parameters of 132 Implants Supporting Locator-Retained Overdentures: A Case Series of 33 Patients. Int J Oral Maxillofac Implants 2013;28:1132-39.
  • Elsyad MA, Elsaih EA, Khairallah AS. Marginal bone resorption around immediate and delayed loaded implants supporting a locator-retained mandibular overdenture. A 1-year randomised controlled trial. J Oral Rehabil 2014;41:608-18.
  • Cakarer S, Can T, Yaltirik M, Keskin C. Complications associated with the ball, bar and Locator attachments for implant-supported overdentures. Med Oral Patol Oral Cir Bucal 2011;16:C953-C59.
  • Kleis WK, Kammerer PW, Hartmann S, Al-Nawas B, Wagner W. A Comparison of Three Different Attachment Systems for Mandibular Two-Implant Overdentures: One-Year Report. Clin Implant Dent Relat Res 2010;12:209-18.
  • Turkyilmaz I. Clinical and radiological results of patients treated with two loading protocols for mandibular overdentures on Branemark implants. J Clin Periodontol 2006;33:233-38.
  • Geckili O, Mumcu E, Bilhan H. The Effect of Maximum Bite Force, Implant Number, and Attachment Type on Marginal Bone Loss around Implants Supporting Mandibular Overdentures: A Retrospective Study. Clin Implant Dent Relat Res 2012;14:e91-e97.
  • Ma SY, Tawse-Smith A, Thomson WM, Payne AGT. Marginal Bone Loss with Mandibular Two-Implant Overdentures Using Different Loading Protocols and Attachment Systems: 10-Year Outcomes. Int J Prosthodont 2010;23:321-32.
  • Hobkirk JA, Abdel-Latif HH, Howlett J, Welfare R, Moles DR. Prosthetic Treatment Time and Satisfaction of Edentulous Patients Treated with Conventional or Implant-Stabilized Complete Mandibular Dentures: A Case-Control Study (Part 2). Int J Prosthodont 2009;22:13-19.
  • Payne AGT, Tawse-Smith A, Duncan WD, Kumara R. Conventional and early loading of unsplinted ITI implants supporting mandibular overdentures - Two-year results of a prospective randomized clinical trial. Clin Oral Implants Res 2002;13:603-09.
  • Meijer HJA, Raghoebar GM, Batenburg RHK, Visser A, Vissink A. Mandibular overdentures supported by two or four endosseous implants: a 10-year clinical trial. Clin Oral Implants Res 2009;20:722-28.

İki implant üstü locator tutuculu tam protez kullanan hastalar: Bir yıllık klinik takip

Year 2015, Volume: 18 Issue: 4, 351 - 358, 20.06.2015

Abstract

Amaç: Bu klinik çalışmanın amacı alt iki implant üstü locator tutuculu ve üst konvansiyonel tam protez kullanan hastaların bir yıl boyunca klinik değerlendirmesinin yapılmasıdır.

Gereç ve Yöntem: Toplam 18 dental implant 9 tam dişsiz hastada alt çene ön bölgeye yerleştirildi. İyileşme sürecini takiben erken yükleme protokolü uygulanarak alt çene implant üstü locator tutuculu ve üst çene konvansiyonel tam protezler üretildi.  Bir yıl süre içinde üç ayda bir kontrol randevuları yapıldı. İmplant başarı oranı, protezde görülen mekanik komplikasyonlar, periimplant dokular (marjinal kemik kaybı, diş taşı mevcudiyeti) ve hasta memnuniyeti değerlendirildi.

Bulgular: İki implant üstü locator tutuculu tam protez kullanan hastaların memnuniyeti, daha önce kullandıkları konvansiyonel total protezlerden belirgin olarak daha yüksektir. İmplant başarı oranı %100’dür. Ancak 7 implant üstü locator tutuculu alt tam protezde herhangi bir mekanik komplikasyon görülmezken, 6. Ay kontrolde iki protezde locator patrikslerinde deformasyon görüldü. Patriksler daha az tutuculuğa sahip farklı renkteki plastik parçalar ile değiştirildi.  

Sonuç: İki implant üstü alt çene tam protezlerde locator tutucular başarılı bir tedavi seçeneğidir. 

References

  • MacEntee MI, Walton JN, Glick N. A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: Three-year results. J Prosthet Dent 2005;93:28-37.
  • Boven GC, Raghoebar GM, Vissink A, Meijer HJA. Improving masticatory performance, bite force, nutritional state and patient's satisfaction with implant overdentures: a systematic review of the literature. J Oral Rehabil 2015;42:220-33.
  • Kimoto K, Garrett NR. Effect of mandibular ridge height on masticatory performance with mandibular conventional and implant-assisted overdentures. Int J Oral Maxillofac Implants 2003;18:523-30.
  • Thomason JM, Kelly SAM, Bendkowski A, Ellis JS. Two implant retained overdentures-A review of the literature supporting the McGill and York consensus statements. J Dent 2012;40:22-34.
  • Trakas T, Michalakis K, Kang K, Hirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent 2006;15:24-34.
  • Alsabeeha NHM, Payne AGT, Swain MV. Attachment Systems for Mandibular Two-Implant Overdentures: A Review of In Vitro Investigations on Retention and Wear Features. Int J Prosthodont 2009;22:429-40.
  • Cune M, Burgers M, van Kampen F, de Putter C, van der Bilt A. Mandibular Overdentures Retained by Two Implants: 10-Year Results from a Crossover Clinical Trial Comparing Ball-Socket and Bar-Clip Attachments. Int J Prosthodont 2010;23:310-17.
  • Krennmair G, Seemann R, Weinlander M, Piehslinger E. Comparison of Ball and Telescopic Crown Attachments in Implant-Retained Mandibular Overdentures: A 5-year Prospective Study. Int J Oral Maxillofac Implants 2011;26:598-606.
  • Elsyad MA, Al-Mahdy YF, Fouad MM. Marginal bone loss adjacent to conventional and immediate loaded two implants supporting a ball-retained mandibular overdenture: a 3-year randomized clinical trial. Clin Oral Implants Res 2012;23:496-503.
  • Cehreli MC, Karasoy D, Kokat AM, Akca K, Eckert S. A Systematic Review of Marginal Bone Loss Around Implants Retaining or Supporting Overdentures. Int J Oral Maxillofac Implants 2010;25:266-77.
  • Bilhan H, Mumcu E, Arat S. The comparison of marginal bone loss around mandibular overdenture-supporting implants with two different attachment types in a loading period of 36 months. Gerodontology 2011;28:49-57.
  • Cehreli MC, Uysal S, Akca K. Marginal Bone Level Changes and Prosthetic Maintenance of Mandibular Overdentures Supported by 2 Implants: A 5-Year Randomized Clinical Trial. Clin Implant Dent Relat Res 2010;12:114-21.
  • Ellis JS, Burawi G, Walls A, Thomason JM. Patient satisfaction with two designs of implant supported removable overdentures; ball attachment and magnets. Clin Oral Implants Res 2009;20:1293-98.
  • Geckili O, Bilhan H, Bilgin T. Impact of mandibular two-implant retained overdentures on life quality in a group of elderly Turkish edentulous patients. Arch Gerontol Geriatr 2011;53:233-36.
  • Balaguer J, Garcia B, Penarrocha M, Penarrocha M. Satisfaction of patients fitted with implant-retained overdentures. Med Oral Patol Oral Cir Bucal 2011;16:E204-E09.
  • Assuncao WG, Barao VAR, Delben JA, Gomes EA, Tabata LF. A comparison of patient satisfaction between treatment with conventional complete dentures and overdentures in the elderly: a literature review. Gerodontology 2010;27:154-62.
  • Troeltzsch M, Troeltzsch V, Brodine AH, et al. Clinical Performance and Peri-implant Parameters of 132 Implants Supporting Locator-Retained Overdentures: A Case Series of 33 Patients. Int J Oral Maxillofac Implants 2013;28:1132-39.
  • Elsyad MA, Elsaih EA, Khairallah AS. Marginal bone resorption around immediate and delayed loaded implants supporting a locator-retained mandibular overdenture. A 1-year randomised controlled trial. J Oral Rehabil 2014;41:608-18.
  • Cakarer S, Can T, Yaltirik M, Keskin C. Complications associated with the ball, bar and Locator attachments for implant-supported overdentures. Med Oral Patol Oral Cir Bucal 2011;16:C953-C59.
  • Kleis WK, Kammerer PW, Hartmann S, Al-Nawas B, Wagner W. A Comparison of Three Different Attachment Systems for Mandibular Two-Implant Overdentures: One-Year Report. Clin Implant Dent Relat Res 2010;12:209-18.
  • Turkyilmaz I. Clinical and radiological results of patients treated with two loading protocols for mandibular overdentures on Branemark implants. J Clin Periodontol 2006;33:233-38.
  • Geckili O, Mumcu E, Bilhan H. The Effect of Maximum Bite Force, Implant Number, and Attachment Type on Marginal Bone Loss around Implants Supporting Mandibular Overdentures: A Retrospective Study. Clin Implant Dent Relat Res 2012;14:e91-e97.
  • Ma SY, Tawse-Smith A, Thomson WM, Payne AGT. Marginal Bone Loss with Mandibular Two-Implant Overdentures Using Different Loading Protocols and Attachment Systems: 10-Year Outcomes. Int J Prosthodont 2010;23:321-32.
  • Hobkirk JA, Abdel-Latif HH, Howlett J, Welfare R, Moles DR. Prosthetic Treatment Time and Satisfaction of Edentulous Patients Treated with Conventional or Implant-Stabilized Complete Mandibular Dentures: A Case-Control Study (Part 2). Int J Prosthodont 2009;22:13-19.
  • Payne AGT, Tawse-Smith A, Duncan WD, Kumara R. Conventional and early loading of unsplinted ITI implants supporting mandibular overdentures - Two-year results of a prospective randomized clinical trial. Clin Oral Implants Res 2002;13:603-09.
  • Meijer HJA, Raghoebar GM, Batenburg RHK, Visser A, Vissink A. Mandibular overdentures supported by two or four endosseous implants: a 10-year clinical trial. Clin Oral Implants Res 2009;20:722-28.
There are 26 citations in total.

Details

Primary Language Turkish
Journal Section Original Research Articles
Authors

Güliz Aktaş

Mustafa Güncü

Şenay Canay

Publication Date June 20, 2015
Submission Date June 20, 2015
Published in Issue Year 2015Volume: 18 Issue: 4

Cite

EndNote Aktaş G, Güncü M, Canay Ş (November 1, 2015) İki implant üstü locator tutuculu tam protez kullanan hastalar: Bir yıllık klinik takip. Cumhuriyet Dental Journal 18 4 351–358.

Cumhuriyet Dental Journal (Cumhuriyet Dent J, CDJ) is the official publication of Cumhuriyet University Faculty of Dentistry. CDJ is an international journal dedicated to the latest advancement of dentistry. The aim of this journal is to provide a platform for scientists and academicians all over the world to promote, share, and discuss various new issues and developments in different areas of dentistry. First issue of the Journal of Cumhuriyet University Faculty of Dentistry was published in 1998. In 2010, journal's name was changed as Cumhuriyet Dental Journal. Journal’s publication language is English.


CDJ accepts articles in English. Submitting a paper to CDJ is free of charges. In addition, CDJ has not have article processing charges.

Frequency: Four times a year (March, June, September, and December)

IMPORTANT NOTICE

All users of Cumhuriyet Dental Journal should visit to their user's home page through the "https://dergipark.org.tr/tr/user" " or "https://dergipark.org.tr/en/user" links to update their incomplete information shown in blue or yellow warnings and update their e-mail addresses and information to the DergiPark system. Otherwise, the e-mails from the journal will not be seen or fall into the SPAM folder. Please fill in all missing part in the relevant field.

Please visit journal's AUTHOR GUIDELINE to see revised policy and submission rules to be held since 2020.