Abstract
Objectives: The aim of this paper was to analysis the effects of disinfectant solutions on polyoxymethylene viscoelastic properties in comparison with polymethyl methacrylate.
Materials and Methods: Polymethyl methacrylate and polyoxymethylene acrylic and 200 mL 5% chlorhexidine gluconate, 2% sodium hypochlorite and one Corega Tabs dissolved in 200 mL water at 40°C were used. The storage modulus, loss modulus, Tanδ and glass transition temperatures of the disinfected acrylic resins were observed with the Thermal Dynamic Mechanical Analyzer.
Results: Lower storage modulus values were observed in the disinfectant solutions at polymethyl methacrylate specimens. The storage modulus showed lower values than the control group at chlorhexidine gluconate, higher values at sodium hypochlorite in the disinfectant solutions at polyoxymethylene specimens. While the glass transition temperatures of polymethyl methacrylate in the disinfectant solutions showed proximal values, the glass transition temperatures of polyoxymethylene in the chlorhexidine gluconate showed lower temperatures (approximately 11 %).
Conclusions: The storage modulus, loss modulus, Tanδ values of polyoxymethylene were lower than those of Polymethyl methacrylate. The Corega Tabs did not affect the viscoelastic properties of polyoxymethylene. Chlorhexidine gluconate and sodium hypochlorite did not affect the viscoelastic properties of polymethyl methacrylate.
Keywords
References
- Chitchumnong P, Brooks SC, Stafford GD. Comparison of three- and four-point flexural strength testing of denture-base polymers. Dent Mater 1989;5:2-5.
- Powell GL, Runsells RD, Saon BA, Whisenant BK. The presence and identification of organisms transmitted to dental laboraties. J Prosthet Dent 1990;64:235-237.
- Pavaria AC, Pizzolitto AC, Machado Giampaolo ET. An infection control protocol: Effectiveness of immersion solutions to reduce the microbial growth on dental prostheses. J Oral Rehabil 2003;30:532-536.
- Lin JJ, Cameron SM, Runyan DA, Craft DW. Disinfection of denture base acrylic resin. J Prosthet Dent 1999;81:202-206.
- McCabe JF, Murray ID, Kelly PJ. The efficacy of denture cleansers. Eur J Prosthodont Res Dent 1995;3:203- 207.
- Neppelenbroek KH, Pavarina AC, Vergani CE, Giampaolo ET. Hardness of heat-polymerized acrylic resins after disinfection and long-term water immersion. J Prosthet Dent 2005;93:171-176.
- Gornitsky M, Paradis I, Landaverde G, Malo AM, Vlly AM. A clinical and microbiological evaluation of denture cleaners for geriatric patients in long- term care institutions. J Can Dent Assoc 2002;68:39-45.
- Robinson RG, McCabe JF, Storer R. Denture bases: The effect of various treatments on acrylic, strength and structure. J Dent 1987;15:159-165.
Details
Primary Language
English
Subjects
-
Journal Section
-
Publication Date
May 9, 2014
Submission Date
May 9, 2014
Acceptance Date
-
Published in Issue
Year 1970 Volume: 17 Number: 3
Cited By
Low-temperature poly(oxymethylene) direct bonding via self-assembled monolayer
Japanese Journal of Applied Physics
https://doi.org/10.7567/JJAP.57.02BB01Effects Of 25%, 37.5% and 50% Musa Acuminata Extract as a Denture Cleanser on the Flexural Strength and Surface Roughness of Acrylic Resin
Journal of Physics: Conference Series
https://doi.org/10.1088/1742-6596/1374/1/012003The Effect of Chlorhexidine Disinfectant Gels with Anti-Discoloration Systems on Color and Mechanical Properties of PMMA Resin for Dental Applications
Polymers
https://doi.org/10.3390/polym13111800Vacuum ultraviolet-induced surface modification of polyoxymethylene plates for photo-activation bonding
International Journal of Adhesion and Adhesives
https://doi.org/10.1016/j.ijadhadh.2023.103548