An Evaluation of the Apical Seal in Oval-shaped Root Canals Prepared with Either Self-adjusting Files or ProTaper Files
Abstract
Objective: This study aimed to evaluate the apical seal obtained with lateral compaction of gutta-percha in oval-shaped root canals prepared with either self-adjusting files or ProTaper rotary files.
Materials and Methods: Twelve pairs of extracted mandibular premolars with oval-shaped root canals were randomly divided into two groups. The first group was biomechanically prepared with ProTaper files, while the self-adjusting file system was used in the second group. The roots were obturated using cold lateral compaction of gutta-percha. Apical microleakage was measured with the computerized fluid filtration method. The results were analyzed statistically using the Mann-Whitney U test.
Results: All of the roots in both groups showed leakage. Group 1 demonstrated significantly less microleakage (p < 0.05).
Conclusions: Instrumentation of oval-shaped canals using a self-adjusting file system with cold lateral compaction of gutta-percha demonstrated significantly greater apical microleakage when compared to ProTaper. The apical leakage with different obturation techniques, combined with self-adjusting files, should be evaluated in further studies.
Keywords
References
- References
- Schilder H. Cleaning and shaping the root canal. Dent Clin North Am. 1974;18:269-96.
- Dow Pr, Ingle JI. Isotope determination of root canal failure. Oral Surgery, Oral Medicine, Oral Pathology 1955; 8, 1100-8
- Delivanis PD, Mattison GD, Mendel RW. The survivability of F43 strain of Streptococcus sanguis in root canals filled with gutta-percha and Procosol cement. J Endod 1983; 9:407-10
- Bergmans L, Van Cleynenbreugel J, Wevers M, Lambrechts P. Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the American Journal of Dentistry. Am J Dent. 2001;14:324-33.
- Glosson CR, Haller RH, Dove SB, DelRio CE. A comparison of root canal preparations using ni-ti hand, ni-ti engine-driven, and k-flex endodontic instruments. J Endod 1995; 21, 146-51.
- Weine FS, Kelly RF, Lio PJ. The effect of preparation procedures on original canal shape and on apical foramen shape. J Endod 1975;1:255-62.
- Metzger Z, Teperovich E, Cohen R, Zary R, Paqué F, Hülsmann M. The self-adjusting file (SAF). Part 3: removal of debris and smear layer-A scanning electron microscope study. J Endod 2010;36:697-702.
Details
Primary Language
English
Subjects
-
Journal Section
-
Authors
Hasan Orucoglu
Tevfik Yavuz
Cavit Yavuz
Yusuf Kaba
Samet Ozden
Publication Date
May 2, 2014
Submission Date
June 24, 2013
Acceptance Date
-
Published in Issue
Year 1970 Volume: 17 Number: 2