Araştırma Makalesi
BibTex RIS Kaynak Göster
Yıl 2022, Cilt: 25 Sayı: 3, 224 - 229, 01.10.2022
https://doi.org/10.7126/cumudj.1103195

Öz

Kaynakça

  • 1. Joiner A. Tooth colour: a review of the literature. J Dent 2004; 32:3-12.
  • 2. Della Bona A, Barrett AA, Rosa V, Pinzetta C. Visual and instrumental agreement in dental shade selection: three distinct observer populations and shade matching protocols. Dent Mater 2009; 25:276-281.
  • 3. Jornung J, Fardal O. Perceptions of patients' smiles: a comparison of patients' and dentists' opinions. J Am Dent Assoc 2007; 138:1544-1553.
  • 4. Samorodnitzky-Naveh, GR., Geiger SB, Levin L. Patients' satisfaction with dental esthetics. J Am Dent Assoc 2007; 138:805-808.
  • 5. Chu SJ, Trushkowsky RD, Paravina RD. Dental color matching instruments and systems. Review of clinical and research aspects. J Dent 2010; 38:2-16.
  • 6. Alshethri SE. Evaluation of color changes in the Vitapan Classical Shade Guide after disinfection. Oper Dent 2014; 39:317-324.
  • 7. Derdilopoulou, FV, Zantner C, Neumann K, Kielbassa AM. Evaluation of visual and spectrophotometric shade analyses: a clinical comparison of 3758 teeth. Int J Prosthodont 2007; 20:414-416.
  • 8. Mete JJ, Dange SP, Khalikar AN, Vaidya SP. Comparative study of shade matching performance of dental students under natural daylight and daylight lamp conditions. Eur J Esthet Dent 2013; 8:92-99.
  • 9. Moscardo AP, Alemany IC. Chromatic appreciation in the clinic and the laboratory. Med Oral Patol Oral Cir Bucal 2006; 11:363-368.
  • 10. Ortolan SM, Persic S, Celebic A, Mehulic K. Comparison of time consumption and color matching results of different dental occupational groups. Int J Prosthodont 2013; 26:478-486.
  • 11. Paul S, Peter A, Pietrobon N, Hammerle CH. Visual and spectrophotometric shade analysis of human teeth. J Dent Res 2002; 81:578-582.
  • 12. Pecho OE, Ghinea R, Perez MM, Della Bona A. Influence of gender on visual shade matching in dentistry. J Esthet Restor Dent 2017; 29:15-23.
  • 13. Pimental W, Tiossi R. Comparison between visual and instrumental methods for natural tooth shade matching. Gen Dent 2014; 62:47-49.
  • 14. Gasparik C, Grecu AG, Culic B, Badea ME, Dudea D. Shade-matching performance using a new light-correcting device. J Esthet Restor Dent 2015; 27:285-292.
  • 15.Robertson AR, Lozano RD, Alman DH, Orchard Se. CIE Recommendations on Uniform Color Spaces, Color-Difference Equations, and Metric Color Terms. Color Res Appl 1977; 2:5-6.
  • 16. Sproull RC. Color matching in dentistry. Part I. The three-dimensional nature of color. J Prosthet Dent 1973; 29:416-424.
  • 17. Sproull RC. Color matching in dentistry. Part II. Practical applications of the organization of color. 1973. J Prosthet Dent 2001; 86:458-464.
  • 18. Munsell AH. A color notation. 11th ed. Baltimore: Munsell Color Co. 1961.
  • 19. Wozniak WT. Proposed guidelines for the acceptance program for dental shade guides. Chicago: American Dental Association 1987.
  • 20. Johnston WM, Kao EC. Assessment of appearance match by visual observation and clinical colorimetry. J Dent Res 1989; 68:819-822.
  • 21. Bolt RA, Bosch JJ, Coops JJ. Influence of window size in small-window colour measurement, particularly of teeth. Phys Med Biol 1994; 39:1133-1142.
  • 22. Johnston WM. Color measurement in dentistry. J Dent 2009; 37:2-6.
  • 23. Haywood VB, Leonard RH, Nelson CF, Brunson WD. Effectiveness, side effects and long-term status of nightguard vital bleaching. J Am Dent Assoc 1994; 125:1219-1226.
  • 24. Cal E, Sonugelen M, Guneri P, Kesercioglu A, Kose T. Application of a digital technique in evaluating the reliability of shade guides. J Oral Rehabil 2004; 31:483-91.
  • 25. Jarad FD, Russell MD, Moss BW. The use of digital imaging for colour matching and communication in restorative dentistry. Br Dent J 2005; 199:43-49.
  • 26. Wee AG, Lindsey DT, Kuo S, Johnston WM. Color accuracy of commercial digital cameras for use in dentistry. Dent Mater 2006; 22:553-559.
  • 27. Caglar A, Yamanel K, Gulsahi K, Bagis B, Ozcan M. Could digital imaging be an alternative for digital colorimeters? Clin Oral Investig 2010; 14:713-718.
  • 28. Smith RN, Rawlinson A, Lath DL, Brook AH. A digital SLR or intra-oral camera: preference for acquisition within an image analysis system for measurement of disclosed dental plaque area within clinical trials. J Periodontal Res 2006; 41:55-61.
  • 29. Chu SJ, Tarnow DP. Digital shade analysis and verification: a case report and discussion. Pract Proced Aesthet Dent 2001; 13:129-136.
  • 30. Smith RN, Collins LZ, Naeeni M, Joiner A, Philpotts CJ, Hopkinson I, et al. The in vitro and in vivo validation of a mobile non-contact camera-based digital imaging system for tooth colour measurement. J Dent 2008; 36:15-20.
  • 31. McLaren EA, Figueira J, Goldstein RE. A technique using calibrated photography and photoshop for accurate shade analysis and communication. Compend Contin Educ Dent 2017; 38:106-113.
  • 32. Tam WK, Lee HJ. Dental shade matching using a digital camera. J Dent 2012; 40:3-10.
  • 33. Miyajiwala JS, Kheur MG, Patankar AH, Lakha TA. Comparison of photographic and conventional methods for tooth shade selection: A clinical evaluation. J Indian Prosthodont Soc 2017; 17:273-281.
  • 34. Cal E, Guneri P, Kose T. Comparison of digital and spectrophotometric measurements of colour shade guides. J Oral Rehabil 2006; 33:221-228.
  • 35. Okubo SR, Kanawati A, Richards MW, Childress S. Evaluation of visual and instrument shade matching. J Prosthet Dent 1998; 80:642-648.
  • 36. Lam WYH, Hsung RTC, Cheng LYY, Pow EHN. Mapping intraoral photographs on virtual teeth model. J Dent 2018; 79:107-110.
  • 37. Tung OH, Lai YL, Ho YC, Chou IC, Lee SY. Development of digital shade guides for color assessment using a digital camera with ring flashes. Clin Oral Investig 2011; 15:49-56.
  • 38. Lasserre JF, Pop-Ciutrila IS, Colosi HA. A comparison between a new visual method of colour matching by intraoral camera and conventional visual and spectrometric methods. J Dent 2011; 39:29-36.

Effectiveness of calibrated digital photography technique in dental shade analyses applications

Yıl 2022, Cilt: 25 Sayı: 3, 224 - 229, 01.10.2022
https://doi.org/10.7126/cumudj.1103195

Öz

Objectives: Although spectrophotometers are commonly used in shade analysis in dentistry; digital cameras, photographic lighting systems, computer programs and photographs have also become the part of this field. The aim of this study was to compare the success of spectrophotometer and calibrated digital photography on shade selection.
Materials and Methods: 3D-Master toothguide (VITA) with 29 tabs was used for the analyses. L, a, b values were determined by a spectrophotometer (Minolta CM-2300D, Konica) and these values were matched with digital photographic measurements. Photographs were transferred to an image analyzing software (Adobe Photoshop CC).
Results: There were significant differences between L* values of the spectrophotometric analyses and digital measurements in 3 different regions of the tab (p<0.05). For the evaluation of ΔE values, Post hoc Bonferroni analysis which was performed between the 3 regions of shade tabs revealed significant difference between the middle (21.92 ± 2.31), incisal (13.67 ± 1.69) and cervical (19.57 ± 2.47) region of the tabs (p<0.05).
Conclusion: Spectrophotometer was found to be a more accurate shade determination technique compared to calibrated digital photography.

Kaynakça

  • 1. Joiner A. Tooth colour: a review of the literature. J Dent 2004; 32:3-12.
  • 2. Della Bona A, Barrett AA, Rosa V, Pinzetta C. Visual and instrumental agreement in dental shade selection: three distinct observer populations and shade matching protocols. Dent Mater 2009; 25:276-281.
  • 3. Jornung J, Fardal O. Perceptions of patients' smiles: a comparison of patients' and dentists' opinions. J Am Dent Assoc 2007; 138:1544-1553.
  • 4. Samorodnitzky-Naveh, GR., Geiger SB, Levin L. Patients' satisfaction with dental esthetics. J Am Dent Assoc 2007; 138:805-808.
  • 5. Chu SJ, Trushkowsky RD, Paravina RD. Dental color matching instruments and systems. Review of clinical and research aspects. J Dent 2010; 38:2-16.
  • 6. Alshethri SE. Evaluation of color changes in the Vitapan Classical Shade Guide after disinfection. Oper Dent 2014; 39:317-324.
  • 7. Derdilopoulou, FV, Zantner C, Neumann K, Kielbassa AM. Evaluation of visual and spectrophotometric shade analyses: a clinical comparison of 3758 teeth. Int J Prosthodont 2007; 20:414-416.
  • 8. Mete JJ, Dange SP, Khalikar AN, Vaidya SP. Comparative study of shade matching performance of dental students under natural daylight and daylight lamp conditions. Eur J Esthet Dent 2013; 8:92-99.
  • 9. Moscardo AP, Alemany IC. Chromatic appreciation in the clinic and the laboratory. Med Oral Patol Oral Cir Bucal 2006; 11:363-368.
  • 10. Ortolan SM, Persic S, Celebic A, Mehulic K. Comparison of time consumption and color matching results of different dental occupational groups. Int J Prosthodont 2013; 26:478-486.
  • 11. Paul S, Peter A, Pietrobon N, Hammerle CH. Visual and spectrophotometric shade analysis of human teeth. J Dent Res 2002; 81:578-582.
  • 12. Pecho OE, Ghinea R, Perez MM, Della Bona A. Influence of gender on visual shade matching in dentistry. J Esthet Restor Dent 2017; 29:15-23.
  • 13. Pimental W, Tiossi R. Comparison between visual and instrumental methods for natural tooth shade matching. Gen Dent 2014; 62:47-49.
  • 14. Gasparik C, Grecu AG, Culic B, Badea ME, Dudea D. Shade-matching performance using a new light-correcting device. J Esthet Restor Dent 2015; 27:285-292.
  • 15.Robertson AR, Lozano RD, Alman DH, Orchard Se. CIE Recommendations on Uniform Color Spaces, Color-Difference Equations, and Metric Color Terms. Color Res Appl 1977; 2:5-6.
  • 16. Sproull RC. Color matching in dentistry. Part I. The three-dimensional nature of color. J Prosthet Dent 1973; 29:416-424.
  • 17. Sproull RC. Color matching in dentistry. Part II. Practical applications of the organization of color. 1973. J Prosthet Dent 2001; 86:458-464.
  • 18. Munsell AH. A color notation. 11th ed. Baltimore: Munsell Color Co. 1961.
  • 19. Wozniak WT. Proposed guidelines for the acceptance program for dental shade guides. Chicago: American Dental Association 1987.
  • 20. Johnston WM, Kao EC. Assessment of appearance match by visual observation and clinical colorimetry. J Dent Res 1989; 68:819-822.
  • 21. Bolt RA, Bosch JJ, Coops JJ. Influence of window size in small-window colour measurement, particularly of teeth. Phys Med Biol 1994; 39:1133-1142.
  • 22. Johnston WM. Color measurement in dentistry. J Dent 2009; 37:2-6.
  • 23. Haywood VB, Leonard RH, Nelson CF, Brunson WD. Effectiveness, side effects and long-term status of nightguard vital bleaching. J Am Dent Assoc 1994; 125:1219-1226.
  • 24. Cal E, Sonugelen M, Guneri P, Kesercioglu A, Kose T. Application of a digital technique in evaluating the reliability of shade guides. J Oral Rehabil 2004; 31:483-91.
  • 25. Jarad FD, Russell MD, Moss BW. The use of digital imaging for colour matching and communication in restorative dentistry. Br Dent J 2005; 199:43-49.
  • 26. Wee AG, Lindsey DT, Kuo S, Johnston WM. Color accuracy of commercial digital cameras for use in dentistry. Dent Mater 2006; 22:553-559.
  • 27. Caglar A, Yamanel K, Gulsahi K, Bagis B, Ozcan M. Could digital imaging be an alternative for digital colorimeters? Clin Oral Investig 2010; 14:713-718.
  • 28. Smith RN, Rawlinson A, Lath DL, Brook AH. A digital SLR or intra-oral camera: preference for acquisition within an image analysis system for measurement of disclosed dental plaque area within clinical trials. J Periodontal Res 2006; 41:55-61.
  • 29. Chu SJ, Tarnow DP. Digital shade analysis and verification: a case report and discussion. Pract Proced Aesthet Dent 2001; 13:129-136.
  • 30. Smith RN, Collins LZ, Naeeni M, Joiner A, Philpotts CJ, Hopkinson I, et al. The in vitro and in vivo validation of a mobile non-contact camera-based digital imaging system for tooth colour measurement. J Dent 2008; 36:15-20.
  • 31. McLaren EA, Figueira J, Goldstein RE. A technique using calibrated photography and photoshop for accurate shade analysis and communication. Compend Contin Educ Dent 2017; 38:106-113.
  • 32. Tam WK, Lee HJ. Dental shade matching using a digital camera. J Dent 2012; 40:3-10.
  • 33. Miyajiwala JS, Kheur MG, Patankar AH, Lakha TA. Comparison of photographic and conventional methods for tooth shade selection: A clinical evaluation. J Indian Prosthodont Soc 2017; 17:273-281.
  • 34. Cal E, Guneri P, Kose T. Comparison of digital and spectrophotometric measurements of colour shade guides. J Oral Rehabil 2006; 33:221-228.
  • 35. Okubo SR, Kanawati A, Richards MW, Childress S. Evaluation of visual and instrument shade matching. J Prosthet Dent 1998; 80:642-648.
  • 36. Lam WYH, Hsung RTC, Cheng LYY, Pow EHN. Mapping intraoral photographs on virtual teeth model. J Dent 2018; 79:107-110.
  • 37. Tung OH, Lai YL, Ho YC, Chou IC, Lee SY. Development of digital shade guides for color assessment using a digital camera with ring flashes. Clin Oral Investig 2011; 15:49-56.
  • 38. Lasserre JF, Pop-Ciutrila IS, Colosi HA. A comparison between a new visual method of colour matching by intraoral camera and conventional visual and spectrometric methods. J Dent 2011; 39:29-36.
Toplam 38 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Sağlık Kurumları Yönetimi
Bölüm Original Research Articles
Yazarlar

Yunus Emre Özden 0000-0002-4080-7744

Ayse Yalnız

Burcu Bal 0000-0002-1849-7006

Zeynep Özkurt Kayahan 0000-0002-3320-9244

Ender Kazazoğlu

Yayımlanma Tarihi 1 Ekim 2022
Gönderilme Tarihi 23 Mayıs 2022
Yayımlandığı Sayı Yıl 2022Cilt: 25 Sayı: 3

Kaynak Göster

EndNote Özden YE, Yalnız A, Bal B, Özkurt Kayahan Z, Kazazoğlu E (01 Ekim 2022) Effectiveness of calibrated digital photography technique in dental shade analyses applications. Cumhuriyet Dental Journal 25 3 224–229.

Cumhuriyet Dental Journal (Cumhuriyet Dent J, CDJ) is the official publication of Cumhuriyet University Faculty of Dentistry. CDJ is an international journal dedicated to the latest advancement of dentistry. The aim of this journal is to provide a platform for scientists and academicians all over the world to promote, share, and discuss various new issues and developments in different areas of dentistry. First issue of the Journal of Cumhuriyet University Faculty of Dentistry was published in 1998. In 2010, journal's name was changed as Cumhuriyet Dental Journal. Journal’s publication language is English.


CDJ accepts articles in English. Submitting a paper to CDJ is free of charges. In addition, CDJ has not have article processing charges.

Frequency: Four times a year (March, June, September, and December)

IMPORTANT NOTICE

All users of Cumhuriyet Dental Journal should visit to their user's home page through the "https://dergipark.org.tr/tr/user" " or "https://dergipark.org.tr/en/user" links to update their incomplete information shown in blue or yellow warnings and update their e-mail addresses and information to the DergiPark system. Otherwise, the e-mails from the journal will not be seen or fall into the SPAM folder. Please fill in all missing part in the relevant field.

Please visit journal's AUTHOR GUIDELINE to see revised policy and submission rules to be held since 2020.